Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. dent. j ; 33(3): 38-46, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384033

ABSTRACT

Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Resumo Este estudo avaliou os instrumentos Reciproc R25 e Pro-R 25 sem uso, após um primeiro e um segundo uso em retratamento endodôntico com perfilômetro 3D por interferometria de luz sem contato, microscópio eletrônico de varredura (MEV) e testes de fadiga cíclica. Vinte dentes unirradiculares foram instrumentados com Reciproc R25 e obturados com guta-percha e cimento endodôntico. Um perfilômetro 3D com uma objetiva 20x usando o software Mx ™ foi usado para avaliar as superfícies da lâmina de corte do Reciproc e Pro-R (n = 5 por grupo) na condição sem uso, após o primeiro e após um segundo uso em procedimentos de retratamento. Após retratamento, o MEV foi usado para avaliar as características topográficas dos instrumentos utilizados. Testes de fadiga cíclica foram realizados para comparar instrumentos novos com instrumentos usados. O teste One-way ANOVA seguido pelo teste de Tukey foi usado para comparar os instrumentos testados nos diferentes estágios. Para comparar os diferentes instrumentos e para avaliação de fadiga cílcica, foi utilizado o Student t-test. Não foram observadas diferenças estatisticamente significantes nas superfícies das lâminas de corte dos instrumentos Reciproc e Pro-R antes e após um e dois usos (p> 0,05). O Reciproc na condição sem uso apresentou maior Sa e Sq quando comparado ao Pro-R (p <0,05). Não foram observadas diferenças entre Reciproc e Pro-R após um e dois usos (p> 0,05). O Reciproc sem uso apresentou maior tempo de fratura do que os instrumentos Pro-R (p<0,05), e apenas o Pro-R apresentou diferenças entre instrumentos novos e usados (p<0,05). Os procedimentos de retratamento com Reciproc e Pro-R não alteraram a topografia da superfície dos instrumentos. Reciproc apresentou maior resistência à fadiga cíclica em comparação com o Pro-R.

2.
Braz. dent. j ; 27(5): 492-496, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-828031

ABSTRACT

Abstract Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.


Resumo Resinas bisacrílicas são usadas em restaurações dentárias provisórias e têm mostrado vantagens em relação a outros materiais. O objetivo deste trabalho foi avaliar a citotoxicidade in vitro de duas resinas compostas bisacrílicas (Protemp 4 e Luxatemp Star), obtidas após 1, 7 e 40 dias da mistura com os componentes da resina, usando um ensaio padronizado empregando células primárias humanas fortemente relacionadas aos tecidos orais. Culturas de células de fibroblastos gengivais humanos foram expostas por 24 h aos extratos das resinas bisacrílicas, esferas de poliestireno (controle negativo) e látex (controle positivo), obtidos após diferentes períodos de incubação, a 37 °C e com 5% CO2. A viabilidade celular foi avaliada usando procedimentos multiparamétricos que envolvem a avaliação sequencial (usando as mesmas células) da atividade mitocondrial (ensaio XTT), a integridade de membrana (teste do vermelho neutro) e a densidade celular total (teste de exclusão do corante cristal violeta). As células expostas aos extratos mostraram viabilidade celular acima de 75% depois de 24 h. Mesmo quando as células foram expostas aos extratos com aumento do tempo de condicionamento, as resinas bisacrílicas não apresentaram efeitos citotóxicos significativos (p<0,05), comparadas ao grupo controle ou em relação às primeiras 24 h de contato com os produtos. Não houve diferença entre os resultados obtidos para as resinas bisacrílicas avaliadas entre as 24 h, 7 e 40 dias depois da mistura. Concluímos que as resinas bisacrílicas Protemp 4 e Luxatemp Star foram citocompatíveis com os fibroblastos gengivais humanos, sugerindo que ambos materiais são adequados para uso em contato com tecidos humanos.


Subject(s)
Humans , Composite Resins , Gingiva/cytology , Fibroblasts/cytology
SELECTION OF CITATIONS
SEARCH DETAIL